Filter Results By:

Products

Applications

Manufacturers

Unit Under Test

assures a constituent's interoperability in a system.

See Also: UUT, EUT, System Under Test, Device Under Test


Showing results: 241 - 250 of 250 items found.

  • JTAG/Background Debug Mode Test System PXI Card

    NX5300 - Marvin Test Solutions, Inc.

    The NX5300 is a single slot 3U PXI device and interfaces to the unit under test via an On-Chip Debug (OCD) or JTAG port. The NX5300 is a high performance JTAG based background debug mode (BDM) diagnostic system designed for functional test, development, programming and troubleshooting of microprocessor and microcontroller based embedded processor systems. Advanced capabilities include simultaneous support of up to 255 devices on a single scan chain, support of sixteen NX5300 systems controlled by single host machine and configurable JTAG/BDM clock rates up to 24 MHz. The NX5300 includes 16 high-speed measurement channels. Each channel can measure logic levels, frequency, count events and perform a CRC check at rates up to 100 MHz.

  • PXI Multiplexer Switch Module

    NI

    PXI Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.

  • PXI RF Multiplexer Switch Module

    NI

    PXI RF Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI RF Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.

  • High Temperature Axial Torsional Extensometers (1200 C or 1600 C)

    Model 7650 - Jinan Testing Equipment IE Corporation

    Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.

  • High Temperature, Low Strain, Extended Performance Capacitive Extensometers

    Model 7650A - Jinan Testing Equipment IE Corporation

    Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.

  • Wide-range High-power DC Power Supply

    IT6500 Series - I-TECH Electronic Co., Ltd

    With ITECH’s latest technology, the IT6500 series offers a full-featured high-performance power test solution. With fast response these DC power supplies provide users with a new level of power supply performance. From 800W to 30 kW, the whole series include more than 100 models. The maximum output voltage and current is up to 1000V and 1200A respectively. With its autoranging capabillity, it also has a super wide range of voltage and current applications. Users can choose the power supply that fits their testing requirements perfectly. In combination with the IT-E501 power dissipater unit, the current sinking capacity of IT6500C can be 100%, 200%, 300% and the power sinking up to 300% of the Sourcing capability. As a high-speed two-quadrant power supply, IT6500C (1800W-30kW) series has a priority function so as to realize high-speed current transition between power supply mode and electronic load mode, to achieve fast switching between sourcing and sinking current, even can achieve seamless switching under certain conditions. IT6512, IT6513 and IT6500C series power supplies provide built-in DIN40839 and ISO-16750-2 testing curves, support solar panel I-V curve simulation function.

  • High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)

    Model 7651 - Jinan Testing Equipment IE Corporation

    Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.

  • Turns Ratio Testers

    TRT Standard Series - IBEKO Power AB

    When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help